32x12V/9Ah in BB-192T battery bank for GP and Master series

BBGP-9-32

Battery Banks for GP and Master series UPS
One Battery Bank per UPS
BBGP-9-32 32x12V/9Ah in BB-192T battery bank for GP and Master series

Features

  • True on-line double conversion design providing galvanic isolation
  • Sine wave Pulse Width Modulation(PWM)
  • IGBT inverter design
  • Pure sine wave output with less than 3% THD
  • Expandable backup time
  • Pre-installed relay connections
  • LED & LCD display
  • Generator compatible

Applications:

  • Camera Surveillance
  • Telephone Systems
  • Computer
  • Point of Sales
  • Gates
  • Servers
  • Industrial
Login for pricing
SKU: 224732 Category:

Specifications
Model GP804 GP806 GP808 GP810
Capacity 4KVA/3.2KW 6KVA/4.8KW 8KVA/6.4KW 10KVA/8KW
Input
Voltage range 176V-264V
Frequency range 40Hz-60Hz
Phase Single Phase
Max. current 20A 30A 40A 50A
Output
Voltage 230V ± 1%
Frequency 50 Hz ±0.5%
Wave form PWM sine wave
Power factor 0,8
Harmonic distortion <3%(linear load)
Battery
Type Sealed lead acid, maintenance free
Configuration 16 x 12V internal or external 16 x 12V external
DC voltage 192VDC
Recharge time 8 hours to 90% capacity after complete discharge
Function
Efficiency 85%”}” data-sheets-textstyleruns=”{“1″:0,”2”:{“2”:{“1″:2,”2″:2300182},”3″:”Arial”,”4″:9}}”>Mains input to mains output >85%
Transfer time 0s
UPS Status indicator Mains, inverter, bypass, UPS abnormal (fault)
Ports RS232, relay contact output
Software Windows 95/98/NT/2000/XP/Vista/7, Windows Server 2003/2008 Linux Debian, Redhat, Fedora, Suse, Ubuntu, Centos, Novell, Mac, FreeBSD
Optional SNMP, AS400 relay contact, External manual bypass
Internal protection 85 Degrees C Output short-circuit: current limit, automatic shutdown and fuse\nUPS Fault: automatically transfer to bypass”}” data-sheets-textstyleruns=”{“1″:0,”2”:{“2”:{“1″:2,”2″:2300182},”3″:”Arial”,”4″:9}}{“1″:51,”2”:{“2”:{“1″:2,”2″:2300182},”3″:”Arial”,”4″:9}}{“1″:309,”2”:{“2”:{“1″:2,”2″:2300182},”3″:”Arial”,”4″:9}}”>Input surge filter, Electronic and fuse protection
Overload: when load reaches 110~150% of UPS rating,transfer to bypass after 3s, automatic recovery Over-temperature: automatically transfer to bypass if UPS internal temperature > 85 Degrees C Output short-circuit: current limit, automatic shutdown and fuse
UPS Fault: automatically transfer to bypass
LCD & mimic panel Input and output voltage, input and output frequency,battery voltage, output load (%), temperature
LED Mains present, bypass, inverter, fault LED
Green LED for normal operation; Yellow LED for warming condition; Red LED for abnormal operation
Audible alarm Mains Disconnect: buzzer beeps once every four seconds Overload or abnormal operation: fault indicator light,buzzer continuously beeps
Environment
Temperature 0-40 Degrees C
Humidity 0-90% (non-condensing)
Physical dimensions
Input/output Terminal Connection
Unit weight w/o battery 95Kg 105Kg 170Kg 182Kg
UPS dimension(W*D*H) 230*635*700mm 305*650*867mm
Battery bank
Dimension(W*D*H)/ weight
BBGP804/6 BBGPM-9-16 BBGPM-9-32 BBGPM-9-48 BBGPM-9-96
Internal in UPS/38.4kg 191x455x345mm/46kg 230x635x700mm/106.8kg 230x635x700mm/145kg 470x635x700mm/290kg
BBGPM-9-144 BBGP-75-16 BBGPM-120-16 BBGPM-120-32 BBGPM-120-48
705x635x700mm/436kg 780x480x1230mm/406kg 780x480x1230mm/542kg 780x970x1230mm/1084kg 780x1460x1230mm/1626kg

Brand

PSS

Datasheet

Download

Data Sheet - BBGPM - Trantech

Copyright © 2021 Trantech: Security Wholesaler. All Rights Reserved.